Left-hand Turnout, Double Ended, WL At Both Ends

Railway WL Control

Point Machine Railway Railway Point Circuit

Railway WL Control

Railway WL Control :- Contact number one on the open switch is used to control the de-energising of the WL in the same way that the AN & BR contacts are used on a set of Four Foots points. In the Normal position (Fig 5.7) the L.H. WL is locking the points. When they are thrown Normal to Reverse, the WL is energised via 1’s contact on the R.H. unit

WL Control

 

In the Reverse position (Fig 5.8) the Right-hand WL is locking the points. When they are thrown Reverse to Normal, the WL is energised via 1’s contact on the Left-hand unit Fig 5.9 shows a typical WL control circuit using contact number one in the respective units.

 

Left-hand turnout, single ended WL control circuit

This section shows a selection of Chairlock point circuits controlled from a ‘V’ style frame

 