The Point Indication Circuit – Railway Signalling Concepts https://www.railwaysignallingconcepts.in Information About Axle Counter,Track Structure Point & Crossing,Cable Schematics,CBTC Equipment,Overlaps,Core Plans,Earthing,ERTMS,Headway Calculation,Hot Axle Box Detectors,Interface Design,Level Crossing,Markers & boards,Bonding Plan Electrical Lockings,Route locking,Automatic Warning Systems AWS,Point Circuit,Equipment Treadle,Track Layout,Track Circuit Interrupters,Train Protection Warning System (TPWS),Slip Siding & Catch Siding. Wed, 01 Jun 2022 08:09:17 +0000 en hourly 1 https://wordpress.org/?v=6.0.11 Railway Point Control Circuit & Point Indication Circuit https://www.railwaysignallingconcepts.in/railway-point-control-circuit-point-indication-circuit/ https://www.railwaysignallingconcepts.in/railway-point-control-circuit-point-indication-circuit/#respond Wed, 01 Jun 2022 06:30:35 +0000 http://www.railwaysignallingconcepts.in/?p=1438 Railway Point Control Circuit & Point Indication Circuit

Railway Point Control Circuit & Point Indication Circuit:Fig 3.2 shows the point control circuit for an ‘N’ style frame. The differences here are the RC and NC lever bands which are used for the energization of the respective Reverse and Normal point auxiliary valves. Note that these lever bands are similar ones for the WL energization. Therefore when the lever is placed either Normal or Reverse the point control circuit and the WL circuits are energized at the same time.

To prevent a race between the two circuits the WL is fed from the electro-pneumatic valve via a 1/4″ (6.35 mm) bore air hose. This small bore ensures that the WL will retract from its port much quicker and before the point motor has started to move the point escapement and therefore catch on the WL.

 

Railway Point Control Circuit & Point Indication Circuit

 

The Point Indication Circuit

Fig 3.3 shows the point indication circuit found on ‘N’ style frames. It looks identical to the ‘V’ style circuit. The difference here is that the indication lamps are fed from 100V AC and are located immediately behind the relevant point lever on the frame, labeled N and R.

 

Railway Point Control Circuit & Point Indication Circuit

‘N’ Style Four Foot Point Circuits.

‘N’ style circuits are similar in principle to those associated with ‘V’ style frames.

Visit:- https://cse.iitkgp.ac.in/ 

Railway Point Control Circuit & Point Indication Circuit

NWKR relay full form

Approach locking in railway signalling in Hindi

Point machine circuit

Back locking in railway signalling

Route locking signalling

Railway signal foundation drawing

Approach locking in Indian Railways

]]>
https://www.railwaysignallingconcepts.in/railway-point-control-circuit-point-indication-circuit/feed/ 0