DC TRACK CIRCUIT – Railway Signalling Concepts https://www.railwaysignallingconcepts.in Information About Axle Counter,Track Structure Point & Crossing,Cable Schematics,CBTC Equipment,Overlaps,Core Plans,Earthing,ERTMS,Headway Calculation,Hot Axle Box Detectors,Interface Design,Level Crossing,Markers & boards,Bonding Plan Electrical Lockings,Route locking,Automatic Warning Systems AWS,Point Circuit,Equipment Treadle,Track Layout,Track Circuit Interrupters,Train Protection Warning System (TPWS),Slip Siding & Catch Siding. Mon, 06 Jun 2022 10:29:27 +0000 en hourly 1 https://wordpress.org/?v=6.0.11 Track Circuit Interrupter Railway  https://www.railwaysignallingconcepts.in/track-circuit-interrupter-railway/ https://www.railwaysignallingconcepts.in/track-circuit-interrupter-railway/#respond Mon, 06 Jun 2022 06:29:05 +0000 http://www.railwaysignallingconcepts.in/?p=1090 Track Circuit Interrupter  Railway 

* Track circuit interrupters are Emergency stop devices. These are provided at designated locations to provide a vital indication that a train has run into a portion of track in which movements are not permitted (e.g. into trap points or Catch points or past FRLs at terminal platforms).

 

* It comprises a main body, narrow neck & head which is designed to break off when a rail vehicle passes over it.

 

* It is bolted to running rail at a position not used by trains for legitimate movement, e.g. beyond the FRL or on stock rail of trap point & shall be insulated from rail.

 

* The TCI relay circuit will operate at 110v 50Hz.The supply will be electrically isolated from the TCI by a 1:1 isolation transformer, due to the susceptibility of TCIs to Earth faults and extraneous traction currents. The vital relays will be powered via a QXR1 transformer rectifier.

 

* These circuit will not be routed through the COC, but will be pre-tested and final connections made for phase commissioning.

 

* The TBTC system will interface with the existing Track Circuit Interrupters to provide automatic detection of an overrun at the ends of lines and sidings including buffer stops and trap points.

 

* In the event that the Track Circuit Interrupter is activated, the TBTC system will close the tracks associated with the device and will ensure that no controlled train movement is allowed into or out of the affected area.

 

* The Relay Rack shall continuously report the status of each track circuit interrupter to the SCS Electronics Rack.

 

* Operation of a track circuit interrupter that is not overridden by the VCC operator shall result in the tracks associated with the device being closed.

 

* Indication of the track circuit interrupter activation shall be provided at the SMC workstation.

 

* Track circuit interrupter activation will not have any affect on RM mode train operation and on route secure aspects.

Track Circuit Interrupters

 

 

Track Circuit Interrupters 1

 

Track Circuit Interrupters 2

]]>
https://www.railwaysignallingconcepts.in/track-circuit-interrupter-railway/feed/ 0
Railway Signalling Track Circuit https://www.railwaysignallingconcepts.in/railway-signalling-track-circuit/ https://www.railwaysignallingconcepts.in/railway-signalling-track-circuit/#comments Thu, 02 Jun 2022 07:30:42 +0000 http://www.railwaysignallingconcepts.in/?p=809 Railway Signalling Track Circuit

Introduction
1. A Track circuit is an Electrical circuit of which the running Rail of a Railway track forms a part. It is employed for indicating the presence of Trains and thereby for controlling Signalling and Block equipment. For the device Track circuit, the following truly holds good.

2. ‘No single Invention in the history of Development of Railway Transportation has contributed more towards Safety and Dispatch Control in that field than the Track circuit. Track circuit forms the foundation for the development of practically every one of the intricate Systems of Railway Signalling in use today wherein the Train itself is continuously active in maintaining its own protection’

3. Track circuits are categorized as DC Track circuits, AC Track circuits, and Electronic Track circuits (AFTC).

Railway Signalling DC Track Circuit

Open Loop DC TC: The circuit gets completed when the track is occupied through the net resistance of the vehicle axles occupying the track circuit. The series resistance is so adjusted as to give sufficient voltage to the relay when track rails are shunted by axles. In this type of track circuit, if any connection breaks, its occupation goes undetected. Hence, it is used only for limited purposes where its failure does not lead to unsafe conditions.

Railway Signalling Track Circuit

 

What is a Closed-Loop DC track circuit?

In this track circuit, the series resistance is called a Regulating Resistance. It regulates the relay voltage so that it falls below the drop-away value when the track is shunted. The fall is caused by the increased voltage drop across the regulating resistance due to a rise in-circuit current when shunted by the vehicles.

Railway Signalling Track Circuit

What is an AC track circuit?

A.C. Track Circuits are provided exclusively in DC traction areas confined to Bombay Divisions of Western and Central Railways. It is possible to work A.C. Track circuits with A.C. traction also, provided the track circuit supply frequency does not have even a harmonic relation with the traction power frequency of 50Hz. 83 1/3 Hz frequency is chosen for this purpose and these track circuits are used in A.C. Traction areas including the places where DC electric traction ends and AC traction starts.

AC Track Circuits is two Types:
1. Single Rail AC Track Circuits
2. Double Rail AC Track Circuits

The length of the Single Rail Track circuit is permitted up to 500 meters. The maximum permissible length of the Double Rail Track circuit is 2,300 meters. The cable lead Resistance at the Relay end shall not exceed 12 Ohms irrespective of the length of Track circuits. The feed end cable Resistance shall not exceed 12 Ohms for Track circuits of 2,100 and 2,300 meters and it can be progressively more with reduction of Track circuit length.

Railway Signalling Track Circuit AC Track Circuit

 

AFTC

• The Audio Frequency Track Circuit (AFTC) is the Jointless type of track circuit
• specifically designed to meet the onerous immunity required in AC or DC electrified areas
• against the high levels of interference present mainly due to traction harmonics.
• The equipment is classified as universal since it can be used in AC, DC, or Non-electrified sections and meets all the requirements of the known track circuits.

SDTC

• The Smartway DTC is a solid-state, fail- safe system which performs, in a safe way, the train detection, rail continuity detection and track to train data transmission functions within a track circuit (TC) using audio frequency signals

Technical Specifications

• TC length: from 20 to 400 m;
• Transversal conductance: from 0 to 0.5 S/km (2 ohm∙km), LTC=400 m;
• from 0 to 1 S/km (1 ohm∙km), LTC=320 m;
• Maximum shunt resistance 0.5 Ohm;
• Overlap length 7 m (joint length);
• Maximum distance between SER and track connections
• 4.5 km if LTC=350 m, Ballast 0.5 S/km (2 ohm∙km);
• 2.0 km if LTC=400 m, Ballast 0.5 S/km (2 ohm∙km);
• 4.5 km if LTC=280 m, Ballast 1 S/km (1 ohm∙km);
• 2.0 km if LTC=320 m, Ballast 1 S/km (1 ohm∙km)

• Cable type 2×1.5 mm2, 40 nF/km, shielded;
• Data transmission speed: 400 bit/s for train detection;500 bit/s for Sacem;
• Rail continuity control throughout track circuit; Yes
• Maximum number of points in TC 2;
• Power supply 220 Vac ±10% at 50 Hz to 60 Hz;
• Temperature range -25°/+70° in the SER; -40°/+80° in the field;
• Frequency carriers (8nos.) 9.5-11.1-12.7-14.3-15.9-17.5-19.1-20.7 kHz;

• Modulation: MSK ±100 Hz at 400 bit/s (Digicode TC)
• : CPFSK ±100 Hz at 500 bit/s ( data);
• Vital Output 12 Vdc on 400 W or 24 Vdc on 1600 W, insulation 1000 Vac;
• DOT 24 Vdc on 1500 W, insulation 1000 Vac;
• Diagnostic RS232 front or RS422/485 rear connector, at 9600 bit/s, packet
• data protocol.

Railway Signalling Track Circuit Block Diagram

 

Frequency and codes arrangement

 

Railway Signalling Track Circuit Frequency and codes arrangement

 

Electrical Joints

 

Railway Signalling Track Circuit Electrical Joints

Electrical Joints, S-Bond

Railway Signalling Track Circuit Electrical Joints, S-Bond

Electrical Joints, Type S-Bond

Railway Signalling Track Circuit ELECTRICAL JOINT, TYPE: S BOND

Electrical Joints: terminal Bond

1.Single rail insulation:- Terminal bond allows delimiting the track circuit at a boundary with an Insulated Rail Joint as shown on
Figure The traction current can continue on the next track circuit by flowing through the terminal bond.

 

Railway Signalling Track Circuit

Railway Signalling Track Circuit

Railway Signalling Track Circuit

2. Double rail insulation:- Terminal bond allows to delimit the track circuit at a boundary with an Insulated Rail Joint on both rails as
shown in Figure.

Double rail insulation

 

ELECTRICAL JOINT, TYPE: DOUBLE ALPHA (TERMINAL ) BOND

ELECTRICAL JOINT, TYPE: DOUBLE ALPHA (TERMINAL ) BOND

INSULATED RAIL JOINT

Electrical Joints: Short circuit Bond

Short circuit bond At a boundary with an area without a track circuit, a short circuit bond can be used as shown in Figure
This configuration does not require any Insulated Rail Joints but the drawback is a dead zone whose length is in relation to the limit shunt value.

 

SDTC principle

SDTC: specific installation: S Bond in crossing

 

 

   Please Watch this Video:-   https://youtu.be/76XWS4EEPWw

 

]]>
https://www.railwaysignallingconcepts.in/railway-signalling-track-circuit/feed/ 1