Left-hand Turnout, Double Ended, WL At Both Ends

Rilway WL Control

Point Machine Railway Railway Point Circuit

wl means in railway, rlwl/wl, how many waiting list tickets get confirmed, can i travel with rlwl ticket, rlwl means, gnwl/wl means in hindi, pqwl, pqwl meaning railway,Right-hand Turnout, Chairlocks/Four Foots, WL At Both Ends, Right-hand Turnout, Single End, With WL, Left-hand Turnout, Single End, With WL, Rilway WL Control, Right-hand Turnout, Double Ended, WL At Both Ends, Left-hand Turnout, Double Ended, WL At Both Ends

Rilway WL Control

Rilway WL Control :- Contact number one on the open switch is used to control the de-energising of the WL in the same way that the AN & BR contacts are used on a set of Four Foots points. In the Normal position (Fig 5.7) the L.H. WL is locking the points. When they are thrown Normal to Reverse, the WL is energised via 1’s contact on the R.H. unit

WL Control

 

In the Reverse position (Fig 5.8) the Right-hand WL is locking the points. When they are thrown Reverse to Normal, the WL is energised via 1’s contact on the Left-hand unit Fig 5.9 shows a typical WL control circuit using contact number one in the respective units.

 

Left-hand turnout, single ended WL control circuit

This section shows a selection of Chairlock point circuits controlled from a ‘V’ style frame

 

Right-hand Turnout, Single End, With WL

Left-hand Turnout, Single End, With WL

Left-hand Turnout, Single End, With WL

Right-hand Turnout, Double Ended, WL At Both Ends

Right-hand Turnout, Double Ended, WL At Both Ends

Left-hand Turnout, Double Ended, WL At Both Ends

Left-hand Turnout, Double Ended, WL At Both Ends

 

 

Leave a Reply

Your email address will not be published. Required fields are marked *